Part E Building Regulations
Part E Building Regulations
home products products products products
Part E Building Regulations

Soundproofing Solutions to Meet New Part E Building Regulations

Separating Timber Floors / Timber Joist Floor / 54 RwdB + Ctr  -  56 LnwdB Application

Part EDownload PDF Data Sheet
Sound Reduction Performance
AirborneImpact
RwdBRwdB+CtrLnwdB
635456
Acoustic Requirement: New Build
Airborne: 45 DnTw+CtrdB
Impact: 62 LnTwdB
Acoustic Requirement: Refurbishment
Airborne: 43 DnTw+CtrdB
Impact: 64 LnTwdB
Components and Fixing Data:
  • 1 x 18mm T&G Chipboard (screwed to)
  • Timber Joists (240 x 48mm at 400mm centres. Joist size to suit application)
  • 52mm Acoustic Quilt (beneath joists)

    Independant Ceiling:
  • Timber Joists (100 x 48mm on hangers at 400mm centres)
  • 2 x 15mm Acoustic Plasterboard (screwed to independant joists)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    59.4Kg/m²
    343mm
    60 minutes
    MODIFICATIONS:
    Adding our Acoustic Membrane between the 2 layers of 15mm plasterboard will improve the above system by between 4-5dB
    Adding Resilient Bars on the independant ceiling joists will improve the above system by around 3-5dB
    Adding soundproofing mats to the top floor will improve the above system by around 3-6dB
    ©Custom Audio Designs 2004