Separating Wall / Double Timber Stud / 52 RwdB +Ctr Application

Part EDownload PDF Data Sheet
Sound Reduction Performance
62 RwdB52 RwdB+Ctr
Part E Acoustic Requirement
New Build
45 DnTw+CtrdB
Refurbishment
43 DnTw+CtrdB
Components and Fixing Data:
  • 2 x 12.5mm Plasterboard (screwed to)
  • 75mm x 50mm Timber Studs (at 600mm centres)
  • 52mm Acoustic Quilt (Between studs)
  • 20mm Clear Cavity
  • 75mm x 50mm Timber Studs (at 600mm centres)
  • 2 x 12.5mm Plasterboard (screwed to studs)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    46.4Kg/m²
    220mm
    60 minutes
    UPRATING:
    Adding our Acoustic Membrane between 2 layers of 12.5mm plasterboard will improve the above system by between 8-10dB