Separating Wall / Double Metal C Metal Stud / 57 RwdB +Ctr Application

Part EDownload PDF Data Sheet
Sound Reduction Performance
66 RwdB57 RwdB+Ctr
Part E Acoustic Requirement
New Build
45 DnTw+CtrdB
Refurbishment
43 DnTw+CtrdB
Components and Fixing Data:
  • 2 x 15mm Acoustic Plasterboard (screwed to)
  • 48mm Metal C Studs (at 600mm centres)
  • 52mm Acoustic Quilt (Between studs)
  • 20mm Clear Cavity
  • 48mm Metal C Stud (at 600mm centres)
  • 2 x 15mm Acoustic Plasterboard (screwed through to studs)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    60.6Kg/m²
    176mm
    60 minutes